Causes of pump breakdown. Centrifugal pump design and failure analysis

Why does air appear in the heating system

There can be many reasons, here are just the main ones:

  • The coolant contains dissolved air, which is released when heated. To a greater extent, this applies to systems where ordinary tap water containing a large amount of dissolved oxygen is used as a heat carrier. When the coolant is heated, oxygen is separated, forming many small bubbles, which create an air lock;
  • The heating circuit was filled with coolant too quickly, as a result of which it was not possible to bleed all the air. The heating system should be filled slowly (on average, 1 floor - 1 hour), especially if it is an extended system with a large number of components;
  • The required pipe slopes were not observed;

Airing the heating system

Automatic air vent in the mine.

  • Air pockets always form after repair work. Repair or replacement of radiators, replacement of fittings, etc. - all this leads to airing of the heating system;
  • Low pressure in the system can lead to an increase in the amount of compressed air, which will also create air pockets;
  • The air vent is out of order or faulty;
  • A leak in the heating system can also cause traffic jams;
  • Oxygen permeability of heating pipes. To a greater extent, this applies to polymer pipes (except for those with an anti-diffusion coating), the walls of which pass oxygen into the system.
  • Sometimes air collects in the corners of the pipeline. This indicates an error during installation: some sections of the pipes were not installed at the level. In such a situation, it is best to embed a tee in the problem area to install an air vent;
  • Some low-quality aluminum batteries react with water, and as a result, air locks will form constantly. In such a situation, one can recommend one thing: use only high-quality heating devices, and not choose which is cheaper. It is recommended to replace a cheap device with a new one of higher quality.

Airing the heating system

Air vent with Danfoss ball valve on the technical floor of the hotel.

Note! In multi-storey buildings, air jams are most often formed in apartments on the last floors, because the air always "tends" to the upper sections of the heating system.

How to get rid of air in pipes

If there is already air in the water supply system of a private house, but it is not equipped with bleed devices, it is necessary:

  1. Switch off the pumping station.
  2. Open all drain taps, drain water and air from the water supply system. Then the pipes are filled again.

You can remove air from the water supply system once and for all with the help of bleed or bleed devices:

  • mechanical valves such as the Mayevsky valve;
  • automatic air vents;
  • ball valves;
  • valves.

Mechanical air relief valve device

from the water supply system is as follows: a cylindrical box, the top is closed with a lid, from the bottom there is a thread for connecting to the water supply. There is a threaded plug in the middle of the cover. A plastic ball-shaped float is suspended inside the cylinder. If there is no air in the hot water supply system, the ball rises to the hole in the plug and closes it tightly under the pressure of the network. As soon as air enters the device, the ball leaves and the air is discharged.Air can enter the system through the bleed valves, which is useful when repairing or inspecting networks and accelerates the drainage of water.

Air extractors are installed at specific points in the water supply system: at the topmost ends, at bends or bends. That is, where there is an increased likelihood of air accumulation.

Homemade air accumulator

In rural water supply systems, air often flows interspersed with water. It is difficult and inconvenient to use such a water supply system, and automation does not always cope: if there is a lot of air, water overflows with a fountain directly from the valve. Therefore, instead of an automatic bleed device to release air in the water supply system, they install air accumulator

... You can do it yourself, this is a tank with a drain pipe and a tap. The diameter of the accumulator must be 5 times the diameter of the water pipe, then it can work efficiently.

The air accumulator is installed at the highest point of the water supply system where it is convenient to manually bleed the air. Air storage tanks are widely used in multi-storey buildings in hot water systems.

How to avoid air entering the system

Several situations must be considered here - when filling the system with a coolant and during its operation. Air vents and Mayevsky taps should be provided in its design, allowing the heating system to be vented. The recommendations given are for a closed, forced circulation system.

Installation of air vents

They are placed in critical places, such as pipe bends or their highest points of location. In many cases, when the heating system is constantly airing, they help to cope with this problem. There are manual and automatic ones.

  1. Manual air vents. These include, first of all, the Mayevsky crane, named after the inventor. Installed at the end of the battery, thanks to it you do not have to think about what to do if the heating system is airborne. With its help, you can independently discharge the accumulated air.
  2. Automatic air vents. They allow you to solve the problem of how to air the heating system without additional participation and costs.

Airing the heating system
Automatic air vent

Manual air vent

Filling the system with water

It is carried out from the bottom up with cold water. In this case, all taps must be open, except for those that work to drain the water. Thanks to this filling, the heating system will not be air-conditioned; as it rises, the water will squeeze air out of it. Filling is carried out smoothly, with a sharp rise in water, the formation of closed volumes and the formation of air bubbles is possible.

Airing the heating system
Filling the heating system with water

As soon as the water has gone through the open tap, it is closed, and so they gradually rise higher until the entire system is filled. After that, it is quite possible to start the pump, if everything is done correctly, then circulation will occur, and there is no need to puzzle over how to pump the heating system.

Automatic air vents

Devices for removing air from plumbing systems are widely available on the market. Float valves are continuous air vents

... They protect the operating system from the accumulation of air and gases. When the pressure in the system drops to atmospheric pressure, the float valve lets air into the pipes. To eliminate the cause of the appearance of air in the water supply system of the house, a check valve is additionally installed. There are air vent models already equipped with a check valve.

Air vents starting action

used to vent air when filling the system with water or to start air during drainage work.

Combined air vents

possess the properties of both previously described devices.

When choosing an air vent, the volume of air to be discharged is taken into account. This indicator can be found in the characteristics of the device. You should not choose a more powerful automatic air vent. Working half-heartedly, it will wear out faster.

For the correct operation of the air vent, the working pressure in the water supply and the quality of the liquid are important. If the density of the resource is below 960 kilograms per cubic meter, floats of a special design are installed.

Video clip about the simplest air vent - the Mayevsky valve:

Reasons for the formation of air congestion

The finished closed-type heating system is hermetically sealed, but this does not guarantee the absence of air bubbles. Where does the gas come from in pipes and radiators?

Air in the heating system appears for the following reasons

:

  1. The coolant is tap water that has not undergone special training - when heated, the air dissolved in the water begins to evolve, and plugs form from small bubbles.
  2. The tightness of the system is broken, and air is gradually sucked in through loose connections.
  3. During the repair work, part of the circuit was disconnected by shut-off valves, some elements were replaced or cleaned, and then the coolant was again fed into the repaired circuit.
  4. The pipeline was laid with violations of the standards - a small angle of inclination of pipes and improper installation of bend points prevents gas bubbles from entering special devices - air vents. As a result, gas accumulates in problem areas and interferes with the normal circulation of the coolant.
  5. If the heating system of a private house fills up very quickly (or when the coolant is supplied not at the lowest point), the liquid is not able to completely displace air from the complex configurations of pipelines and radiators.
  6. Air vents missing or incorrectly located. Also, the reason for the incorrect operation of the device for bleeding air is its contamination with mechanical impurities in the unfiltered coolant.

Airing the heating system
Mayevsky's manual tap on the radiator
Gas formation in aluminum radiators should be considered separately. When the metal comes into contact with a weakly alkaline coolant, hydrogen is released, which accumulates at the highest point of the heater. If the radiator is not equipped with an air vent, over time the gas plug will not allow the coolant to freely pass through the internal channels of the heater.

Which leads to airborne

There are a number of reasons that affect the ingress of air into the vehicle. But, as a rule, this happens on old and used cars.

So, here are a few common reasons for which air starts to enter the system.

  1. In the fuel pump, the oil seals are loose or they are worn out.
  2. The fuel supply pipes have cracked, the clamps that connect and fix them have rotted. Metal hoses rust over time, especially when the tube enters the fuel tank.
  3. The fuel filter is not properly sealed.
  4. A PVC hose is used as a return line (a pipe through which the fuel returns to the tank). Any violation of the tightness of this important line leads to a similar situation.
  5. Problems with the seal of the high pressure pump (high pressure pump) in the area of ​​the drive shaft.
  6. Poor fuel pump cover seal.

Most of the reasons are related to seals. Therefore, it is extremely important to check them regularly, replace old and dry ones.

Separately, I would like to focus on the injection pump. This pump itself is very complex in terms of design, and in addition to weak seals, it has many other possible places for air leaks. Qualified diagnostics of high-pressure fuel pumps can only be carried out by specialists, so if in doubt, it is advisable to show them the pump right away.


Injection pump

Above were given the natural reasons for airborne vehicles. They arise due to aging, and this process cannot be stopped, but it can be prolonged. There are also reasons that led to air leaks due to improper repair operations.

For example, the fuel filter was replaced. Experts say that often a new filter is either installed incorrectly or a low-quality version is installed. The latter happens all the time nowadays. It seems like I bought a part in a store, but it turns out - a marriage, a fake. As for the replacement, it must be carried out competently and carefully. Often amateurs normally install a repaired element, but inadvertently spoil the fuel connections, hook them with a screwdriver or something else. As a result, a hole appears, where the air comes from.

You should be aware that airing of the vehicle occurs when any line or branch is damaged, be it a return line or a supply.

It also happens that air enters the system due to a bad road. You are racing, for example, at high speed, and with one wheel you fly into a hole. The flight is normal, the movement continues, you are an ace. But with this maneuver, the fuel in the tank goes completely to one side, while the pump grabs air instead of fuel. This happens on machines with flat tanks.

How to prevent the formation of air in the heating system

Even at the design stage of the heating system, it is necessary to install all the elements in such a way as to ensure the free, unhindered "circulation" of the air that is formed when the heat carrier is heated.

All closed systems must be equipped with air vents.

Airing the heating system

Separator of air and sludge Honeywell HF49.

In closed heating systems, air separators can be used, which allow you to completely clean the coolant, both from dissolved air and from air in the form of small and large bubbles. The separator is designed to retain and remove air particles.

We fill the system correctly

The easiest way is to pump water or antifreeze into pipelines connected to an open expansion tank. To do this, open all valves (except for the drain valve) and, by connecting a hose to the make-up connection, fill the lines and radiators with coolant

In this matter, it is important not to rush and allow air to leave the system on its own through the expansion tank.

Advice. After filling, turn on the circulation pump and the boiler, and then warm up all the heating devices. Then bleed the remaining air from them through the Mayevsky taps. Do not forget to air the pump before starting, as described above.

Airing the heating system

Now about how to release air from batteries and pipelines of a closed heating system of a private house. The proposed technique, constantly practiced by our expert - plumber Vitaly Dashko. is executed in the following order:

  1. Open all shut-off valves of the main circuits (except for the drain).
  2. Shut off all radiator taps, excluding the very last batteries at the ends of the hinges, so that there is circulation through them.
  3. Get an assistant to work. His task is to be in the boiler room and maintain the pressure in the network at 1 bar using a pressure pump or through the make-up branch from the water supply.
  4. After opening the water supply, fill the main lines, expansion tank and boiler tank. Air must be vented through the safety group valve and air vent at the highest point (if present).
  5. Go to the first radiator from the boiler and open both taps at the same time (slowly). Let the air out through the Mayevsky valve and close the valves again. The assistant during this time does not allow the pressure to fall below 1 bar.
  6. Repeat the operation on all batteries, then turn on the circulation pump and start the heat generator. When the lines begin to warm up, open all the radiator valves one by one and remove the remaining air from them again.

Airing the heating system

An important point.Before squeezing out the air plugs from the radiators, be sure to bleed the air from the circulation pump and turn it on for 5-10 minutes to bleed the pipelines.

After the heating devices have completely warmed up, the pressure in the system should be within 1.3-1.6 bar. This completes the procedure. If there are warm floors in the system, then they must be filled last, using the same algorithm (for a cold one!). That is, having pumped up the pressure in the main line, you need to alternately open and close the floor circuits, letting the air through the manifold valves, and then warm up and adjust the flow rate of the coolant.

Note regarding the installation of automatic air vent valves. Such a device should always be in the boiler safety group, and the second, third, and so on - only if the lines pass above the radiators. With the lower wiring in a one-story house, air accumulates in the batteries, since they are higher than the pipelines, and it is not necessary to install valves on them.

Causes and consequences

The following factors are the reason for the occurrence of air congestion:

  1. During the installation, mistakes were made, including the wrong places of bends were made or the slope and direction of the pipes were incorrectly calculated.
  2. Too fast filling of the heating medium in the system.
  3. Incorrect installation of air vent valves or lack of them.
  4. Insufficient amount of coolant in the network.
  5. Loose connections of pipes with radiators and other parts, due to which air gets inside the system from the outside.
  6. The first start and excessive heating of the coolant, from which oxygen is more actively removed under the influence of high temperature.

The greatest harm air can bring to systems with forced circulation. During normal operation, the bearings of the circulation pump are always in the water. When air passes through them, they lose lubrication, which leads to damage to the sliding rings due to friction and heating, or completely disables the shaft.

Water contains dissolved oxygen, carbon dioxide, magnesium and calcium, which, when the temperature rises, begin to disintegrate and settle on the pipe walls in the form of limescale. Places of pipes and radiators filled with air are more susceptible to corrosion than others.

Signs by which you can determine if there are air locks in pipes and radiators

Due to the air in the heating system, the batteries heat up unevenly. When checked by touch, their upper part has a noticeably lower temperature compared to the lower one. Voids do not allow them to warm up properly, therefore, the room is heated worse. Due to the presence of air in the heating system, with strong heating of water in pipes and radiators, noise appears, similar to clicks and overflow of water.

You can determine the place in which the air is located with an ordinary tap. Where there is no coolant, the sound will be more sonorous.

Note! Before removing air from the network, you should find the cause of its appearance and eliminate it. Especially carefully check the network for tightness

When heating is started, it is extremely difficult to identify loose connections, since water quickly evaporates on a hot surface

Especially carefully check the network for tightness. When the heating is started, it is extremely difficult to identify loose connections, since water quickly evaporates on a hot surface.

Causes of breakdowns and repairs by the master

Anything can be the cause of a pump breakdown. Perhaps the pump was running dry, which led to the failure of the stuffing box seal or overheating of the windings, followed by their burnout. Many manufacturers indicate on the label that you need to monitor the presence of water in the system.However, it should always be borne in mind that the pump must be repaired by a professional. It will be easier for the technician to diagnose the problem and repair the device. Also, a professional will give a guarantee for the work done, which is consumer protection in case of problems with the device. The specialist has special knowledge to carry out this type of work. The “self-taught” master will spend more time on repairs, plus he may make a mistake, since he does not know all the intricacies of a specialist's work. This will lead to higher costs than contacting a specialist.

When pumps are operated in violation of the operating rules and outdated equipment, breakdowns occur. Also, equipment can fail due to a long service life.

The ideal option is to replace the broken centrifugal pump with a new one or take it to a service center if the breakdown is minor. But not everyone can afford it. To save money, many people repair pumps on their own.

How to remove an airlock from the engine cooling system

So, let's start with simple cars (old foreign cars, domestic auto industry). On such cars, air removal from the cooling system is carried out as follows:

  1. It is enough to drive the car onto the overpass. This must be done in such a way that the front part is slightly raised.
  2. Next, you need to unscrew a special plug on the radiator, after which the engine can be started.
  3. After several minutes of work at XX, air is vented from the engine cooling system.

However, this method will not help solve the problem on more modern cars. On such vehicles, the cooling system is of a completely closed type, that is, the air must be "expelled" for air release. To do this, you can go in two ways.

The first method involves unscrewing the expansion tank cap, then the engine with an open cover works for XX for a while, then you need to get into the car and turn off intensively, raising the speed to 3-3.5 thousand rpm. Next, the lid must be screwed on and the system operation checked.

If this method does not help, then the upper branch pipe that goes from the stove is weakened. You need to be prepared for the fact that the antifreeze itself will begin to flow out. Next, the engine starts, and you need to monitor when air bubbles disappear from the flowing coolant. Their disappearance will indicate that the airlock has been successfully removed from the system. Let's consider this method in more detail using the example of the VAZ "Kalina" model.

Before starting work, you should prepare keys for dismantling the plastic protective elements. You will also need a screwdriver to loosen and then tighten the clamps.

So, the first thing to do is remove the plastic protection. This protection on the specified vehicle model is attached to the body using studs that have rubber seals. Further, the clamp must be removed from the upper or lower branch pipe. Now you should unscrew the cap of the expansion tank

If the engine is hot, be careful, as hot coolant may spill out of the reservoir! Then the neck of the tank is covered with a clean rag. Next, a suitable rubber tube should be pulled over the neck

After that, you need to supply some air into the tank by blowing into the tube. It is advisable to do this with a compressor.

Remember, coolant is a strong poison! Only in extreme cases, blow out the tank with your mouth, while do not allow the coolant to get inside, in the eyes or on the skin, do not inhale the vapors!

  • After air is supplied to the tank, antifreeze should begin to flow from the branch pipe from which the clamp was previously removed. After that, you need to make sure that there are no air bubbles in the flowing coolant, then quickly put the pipe on the fitting, put the clamp in place and tighten it. At this stage, the air release process can be considered complete.
  • Next, you will need to bring the coolant level to normal (usually "cold" is poured 4-5 mm. Higher o, since after warming up the internal combustion engine, the liquid will increase in volume and rise to o.
  • After that, the engine can be started and warmed up. In some cases, as part of this procedure, you need to slightly screw the cap of the expansion tank without tightening it. Then you should let the power plant idle, periodically increasing the speed. This method will remove excess air that may have formed when adding fluid.
  • If everything is in order, the cover can be screwed on more tightly, but do not try to tighten it too tightly.

Pump

The drain pump is a small, low power electric motor. Over time and under the influence of overloads, it burns out. To check this, you need to directly apply voltage to its terminals using a carrier.

Expert opinion

I work in the field of household appliances repair. Great experience in refurbishing washing machines and dishwashers.

Ask a Question

When buying a new one, it is necessary to take into account the attachment of the pump to the "snail".

In modern models, it is as follows:

  • on 3 screws;
  • on three latches;
  • on 4 latches;
  • on 8 latches.

drain pump.

What threatens the appearance of air congestion

The presence of air in the lines will not allow providing the radiators with the required amount of coolant, which means that the heating devices will not give out the required heat and the room temperature will be lower than the desired one. The noise inherent in overcoming an air obstacle in the system will not cause irritation during the daytime, but at night it will not let you fall asleep. In places where traffic jams are formed, the internal environment becomes aggressive, which contributes to the active formation of rust.

The most unpleasant thing is overheating. The presence of air in the heat exchanger or in the heat “supply” line will impede the movement of the coolant, and an increase in temperature can damage the coil or pump.

The ability to bleed air from the boiler or individual sections will allow owners of private houses with autonomous heating to get rid of traffic jams on their own, preventing harmful consequences without resorting to the help of service providers.

Cavitation as a cause

Before starting to clarify the issue, it is important to know: the pumps are installed depending on the diameter of the well! For sizes of 100 mm, a submersible pump is suitable, a smaller diameter requires a circular or plunger pump.

What is cavitation? This is a violation of the continuity of the fluid flow, otherwise it is the filling of water with bubbles. Cavitation occurs in those areas where the pressure drop reaches a critical rate. The process is accompanied by the formation of voids in the flow, the release of bubble formations of air that appear due to vapors and gases released from the liquid. Being in the area of ​​reduced pressure, the bubbles can increase and collect in large void cavities, which are carried away by the fluid flow and, in the presence of high pressure, are destroyed without a trace, and in the conditions of an ordinary household well, they often remain and it turns out that the pump during operation pumps air bubbles from wells without giving out the required volume of water.

Revealing the cavitation zone is sometimes impossible due to the lack of special instruments, but it is important to know that such a zone can be unstable. If the deficiency is not eliminated, then the consequences can be devastating: vibration, dynamic effects on the flow - all this leads to pump breakdown, because each device is characterized by the specified value of the cavitation margin. Otherwise, the pump has a minimum pressure, within which the water entering the device retains its density properties. With pressure changes, cavities and air voids are inevitable. Therefore, the selection of the pump should be carried out depending on the volume of water required to meet household and household needs.

The destruction of air bubbles occurs only when they are transferred by a stream to the area of ​​increased pressure, which is accompanied by small hydraulic shocks. The frequency of impacts leads to the appearance of a hissing sound, which can be used to determine the presence of air in the well.

Determination of the site of plug formation and its removal

How can you tell if there is air in the radiator? Usually, the presence of air is indicated by extraneous sounds, such as gurgling, water flow. To ensure full circulation of the coolant, it is imperative to remove this air. With a complete airing of the system, you must first determine the places of formation of plugs by tapping with a hammer on the heating devices. Where there is an airlock, the sound will be more resonant and strong. Air is collected, as a rule, in radiators installed on the upper floors.

Realizing that there is air in the heater, you should take a screwdriver or wrench and prepare a container for water. Having opened the thermostat to the maximum level, you need to open the valve of the Mayevsky tap and substitute the container. A slight hiss will indicate that air is coming out. The valve is kept open until water flows out and only then is it closed.

Airing the heating system
Elimination of the airlock in the heating battery with the help of the Mayevsky crane installed on it: the valve is opened with a special key or manually and kept open until water appears

It happens that after carrying out this procedure, the battery does not heat up for long or not well enough. Then it needs to be blown out and washed, since the accumulation of debris and rust in it can also cause air to appear.

Airing the heating system
If after bleeding the air the battery still does not heat up well, try draining about 200 g of the coolant to make sure that the air lock is completely removed. If it does not help, but you need to blow out and rinse the radiator from possibly accumulated dirt

If there is still no improvement, check the filling level of the heating system. Air pockets can also form at pipe bends.

Therefore, it is important during the installation process to observe the direction and magnitude of the slopes of the distribution pipelines. In places where the slope for any reason differs from the project, air vent valves are additionally installed

In aluminum radiators, air locks are formed more intensively due to the poor quality of the material. As a result of the reaction of aluminum with the coolant, gases are formed, therefore, they must be regularly removed from the system. In such situations, it is recommended to replace aluminum radiators with devices of better quality materials with an anti-corrosion coating and install air vents. In order for the heating of the rooms to be normal, before filling the heating system with water, it is necessary to timely take care of removing air from it, which prevents the normal movement of the coolant, and then in winter your house will be warm and comfortable.

Operation requirements

If there are malfunctions in the system for pumping liquid, it should be remembered that the reason may not always lie in the equipment itself. Therefore, the pumps should be disassembled only when all third-party factors are checked. In order to avoid problems that may arise during operation, several basic rules must be followed.

Ensure that the working container is completely filled with liquid before starting work. In the event that it is not fully filled or there are large noises at the same time, it is necessary to open the air outlet valves, which should be located on the unit body. To expel all the air from the system, it is necessary to fill the suction pipe and the pump itself with working fluid.This must be done until all the air has left the pump.

Avoid blockages in the suction pipe (hose), impeller (impeller) or protective screens. This can lead to a weakening of the head and the appearance of pulsations during delivery. In order to avoid such blockages, you need to install protective grilles or coarse filters. If, while meeting these requirements, the required head force is not achieved, then the impeller rotation speed must be increased.

During the operation of the pump, during the increase in power and increase in flow, overloads of its motor may occur. To avoid this, you can install a special valve on the outlet pipe. With its help, it will be possible to regulate the required flow without bringing the engine to overheating.

Special attention should be paid to whether the direction of rotation of the pump shaft corresponds to the required one. If this direction is wrong, then the tightening force of the nuts on the working shaft will weaken, which will lead to its runout and cause breakage of the housing elements. It can also lead to complete seizure of the pump shaft.

Back to the table of contents

Top feed in an apartment building - how to release air

Top spill buildings have the following features:

  • the filling of the supply is located on the technical floor, and the return one is in the basement;
  • each riser is a jumper between them, shutdown is possible both from the bottom and from the top;
  • the feeding filling is done with a slight slope;
  • on it, at the very top, there is an expansion device with a relief valve, while the discharge is often taken out through all floors to the elevator unit in the basement or as close to it as possible.

The function of the air vents is assigned to the vent on the expansion device. Thanks to the outlet of the discharge to the basement, the start of heating in the fall is simplified.

Airing the heating system

Rating
( 1 estimate, average 5 of 5 )

Heaters

Ovens